Click to reach us online

Thermal-shock-proof Inclinometer

Vigor Technology MEMS Inclinometer / Thermal-shock-proof Inclinometer

Features 

  • Withstand 1200℃ thermal shock within 5 minutes 
  • Special cable protective cover 
  • IP65 protection grades 
  • High resolution & accuracy& stability 
  • Particular high temperature material, structure designX sensitive axis mark 



Applications 
Electric power, chemical, metallurgy and other industries such as high-temperature region 
Metallurgical heating treatment equipment, high-temperature fluid pipeline equipment 
Missile launch vehicles, launchers, aircraft carriers and other military equipment exposed to high-temperature region

Thermal-shock-proof Inclinometer
Measurement range ±5° ±10° ±15° ±30° ±45° ±60°
Combined absolute
accuracy ①(@25 ℃ )
±0.01° ±0.015° ±0.02° ±0.04° ±0.06° ±0.08°
Accuracy
Subroutine
parameter

Absolute linearity(LSF,%FS)

±0.06 ±0.03 ±0.03 ±0.03 ±0.02 ±0.02

Cross-axis sensitivity②

±0.1%FS
Offset ③ ±0.005° ±0.008°
Repeatability ±0.0025°
Hysteresis ±0.0025°
Allowed installation misalignment④ ±4.0° ±3.0° ±2.5° ±1.5° ±1.2° ±1.2°
Input-axis misalignment ≤±0.1°
Sensitivity temperature drift
coefficient(max.)
≤100ppm/℃ ≤50ppm/℃
Offset temperature drift
coefficient(max.)
≤0.003°/ ℃
Offset turn on repeatability⑤ ±0.008°
Resolution 0.0025°
Long-term stability(1 year) ≤0.02°
Measurement axis 1 or 2 axis
Temperature sensor Range: -50~125℃, Accuracy:±1℃
Output RS232, RS485, RS422, CAN
RS232 data format 115200 baud,8 data bit,1start bit,1start bit,none parity
Cold start warming time 60s
Response time 0.3s(@t90)
Refresh rate 5Hz, 10Hz, 20Hz
Response frequency 3Hz @-3dB
Power supply 9~36VDC
Power consumption Average working current≤50mA, average power≤1.5W(25℃&24VDC)
Operation temperature range Long-term working: -40~500℃
1200℃ thermal-shock within 5min.
Storage temperature range -60~100℃
EMC According to EN 61000
Insulation resistance 100MΩ
MTBF ≥25000 h/times
Shock 100g@11ms, three-axis, half-sine
Vibration 8grms, 20~2000Hz
Protection IP65(Optional IP67)
Weight 600g(without connector and cable)

① Combined absolute accuracy means the compositive value of sensor's absolute linearity, repeatability, hysteresis, offset and cross-axis sensitivity error.(in room temperature condition) as
Δ=±
②The cross-axis sensitivity means the angle that the tilt sensor may be banked to the normal tilt direction of sensor. The cross-axis sensitivity (± 0.1%FS)shows how much perpendicular acceleration or inclination is coupled to the inclinometer output signal. For example, for the single-axis inclinometer withrange ±30°(assuming the X-axis as measured tilt direction), when there is a 10° tilt angle perpendicular to the X-axis direction(the actual measuring angle is no change, example as +8.505°), the output signal will generate additional error for this 10° tilt angle, this error is called as cross-axis sensitivity error.SST300`s cross-axis sensitivity is 0.1%FS, the extra error is 0.1%×30°=0.03°(max), then real output angle should be +(8.505°±0.03°). In SST300 series,this error has been combined into the absolute accuracy
③ Offset means that when no angle input (such as the inclinometer is placed on an absolute level platform), output of sensor is not equal to zero,the actualoutput value is zero offset value.
④ Allowed installation misalignment means during the installation, the allowable installation angle deviation between actual tilt direction and sensor's nature measure ment direction. In general, when installed,SST300 sensor is required that the measured tilt direction keep parallel or coincident with sensor designated edge, this parameter can be allowed a certain deviation when sensor is installed and does not affect the measurement accuracy.
⑤ Offset turn on repeatability means the repeatability of the sensor in repeated by supply power on-off-on many times.

 

Dimensions

Wiring

Ordering