Click to reach us online

Type MH3

NGT - Thin Type
Type MH3

Type MH3
Operation Temp 0℃~ 70℃
Differential Standards:10K~30K
Temp Tolerance Standards:±5~10℃ ※Depend on Operation Temp
Max Ambient Temp 70℃
Resistance between Terminals

 

Less than 30mΩ (Initial value)

Insulation Resistance Not less than 1,000MΩ/DC500V
Dielectric strength Not less than AC1,500V/1min.
Not less than AC1,800V/1sec
Endurance More than 10,000cycles (Standards)
NGT - Type MH3NGT - Type MH3

03型フェノールケース

  • Compliance with RoHS Directives.
  • This is not splash or water proof type.
  • Please feel free to ask us in case that operation temp, Diffential, Temp Tolerance is not standard.
  • JIA approval model is normal close type only.